Newsflash:
Log in
     
Electricity Generation PDF  | Print |  E-mail

Electricity Generation

Grid management system

Typical components of a wind turbine (gearbox, rotor shaft and brake assembly) being lifted into position

Electricity generated by a wind farm is normally fed into the national electric power transmission network. Individual turbines are interconnected with a medium voltage (usually 34.5 kV) power collection system and communications network. At a substation, this medium-voltage electrical current is increased in voltage with a transformer for connection to the high voltage transmission system. The surplus power produced by domestic microgenerators can, in some jurisdictions, be fed back into the network and sold back to the utility company, producing a retail credit for the consumer to offset their energy costs.[14][15]

Induction generators, often used for wind power projects, require reactive power for excitation so substations used in wind-power collection systems include substantial capacitor banks for power factor correction. Different types of wind turbine generators behave differently during transmission grid disturbances, so extensive modelling of the dynamic electromechanical characteristics of a new wind farm is required by transmission system operators to ensure predictable stable behaviour during system faults (see: Low voltage ride through). In particular, induction generators cannot support the system voltage during faults, unlike steam or hydro turbine-driven synchronous generators (however properly matched power factor correction capacitors along with electronic control of resonance can support induction generation without grid). Doubly-fed machines, or wind turbines with solid-state converters between the turbine generator and the collector system, have generally more desirable properties for grid interconnection. Transmission systems operators will supply a wind farm developer with a grid code to specify the requirements for interconnection to the transmission grid. This will include power factor, constancy of frequency and dynamic behaviour of the wind farm turbines during a system fault.[16][17]

[edit] Capacity factor

Worldwide installed capacity 1997-2008, with projection 2009-2013 based on an exponential fit. Data source: WWEA

Since wind speed is not constant, a wind farm's annual energy production is never as much as the sum of the generator nameplate ratings multiplied by the total hours in a year. The ratio of actual productivity in a year to this theoretical maximum is called the capacity factor. Typical capacity factors are 20-40%, with values at the upper end of the range in particularly favourable sites.[18][19] For example, a 1 megawatt turbine with a capacity factor of 35% will not produce 8,760 megawatt-hours in a year (1x24x365), but only 1x0.35x24x365 = 3,066 MWh, averaging to 0.35 MW. Online data is available for some locations and the capacity factor can be calculated from the yearly output.[20][21]

Unlike fueled generating plants, the capacity factor is limited by the inherent properties of wind. Capacity factors of other types of power plant are based mostly on fuel cost, with a small amount of downtime for maintenance. Nuclear plants have low incremental fuel cost, and so are run at full output and achieve a 90% capacity factor.[22] Plants with higher fuel cost are throttled back to follow load. Gas turbine plants using natural gas as fuel may be very expensive to operate and may be run only to meet peak power demand. A gas turbine plant may have an annual capacity factor of 5-25% due to relatively high energy production cost.

According to a 2007 Stanford University study published in the Journal of Applied Meteorology and Climatology, interconnecting ten or more wind farms can allow an average of 33% of the total energy produced to be used as reliable, baseload electric power, as long as minimum criteria are met for wind speed and turbine height.[23][24]

Intermittency and penetration limits

Diagram of the TVA pumped storage facility at Raccoon Mountain Pumped-Storage Plant

Electricity generated from wind power can be highly variable at several different timescales: from hour to hour, daily, and seasonally. Annual variation also exists, but is not as significant. Because instantaneous electrical generation and consumption must remain in balance to maintain grid stability, this variability can present substantial challenges to incorporating large amounts of wind power into a grid system. Intermittency and the non-dispatchable nature of wind energy production can raise costs for regulation, incremental operating reserve, and (at high penetration levels) could require an increase in the already existing energy demand management, load shedding, or storage solutions or system interconnection with HVDC cables. At low levels of wind penetration, fluctuations in load and allowance for failure of large generating units requires reserve capacity that can also regulate for variability of wind generation.

A series of detailed modelling studies which looked at the Europe wide adoption of renewable energy and interlinking power grids using HVDC cables, indicates that the entire power usage could come from renewables, with 70% total energy from wind at the same sort of costs or lower than at present. Intermittency would be dealt with, according to this model, by a combination of geographic dispersion to de-link weather system effects, and the ability of HVDC to shift power from windy areas to non-windy areas.[25][26]

Pumped-storage hydroelectricity or other forms of grid energy storage can store energy developed by high-wind periods and release it when needed.[27] Stored energy increases the economic value of wind energy since it can be shifted to displace higher cost generation during peak demand periods. The potential revenue from this arbitrage can offset the cost and losses of storage; the cost of storage may add 25% to the cost of any wind energy stored, but it is not envisaged that this would apply to a large proportion of wind energy generated. Thus the 2 GW Dinorwig pumped storage plant adds costs to nuclear energy in the UK for which it was built, but not to all the power produced from the 30 or so GW of nuclear plants in the UK.

In particular geographic regions, peak wind speeds may not coincide with peak demand for electrical power. In California and Texas, for example, hot days in summer may have low wind speed and high electrical demand due to air conditioning. Some utilities subsidize the purchase of geothermal heat pumps by their customers, to reduce electricity demand during the summer months by making air conditioning up to 70% more efficient;[28] widespread adoption of this technology would better match electricity demand to wind availability in areas with hot summers and low summer winds. Geothermal heat pumps also allow renewable electricity from wind to displace natural gas and heating oil for central heating during winter, when winds tend to be stronger in many areas. Another option is to interconnect widely dispersed geographic areas with a relatively cheap and efficient HVDC "Super grid". In the USA it is estimated that to upgrade the transmission system to take in planned or potential renewables would cost at least $60 billion[29]. Total annual US power consumption in 2006 was 4 thousand billion kilowatt hours. [30] Over an asset life of 40 years and low cost utility investment grade funding, the cost of $60 billion investment would be about 5% p.a. ie $3 billion p.a. Dividing by total power used gives an increased unit cost of around $3,000,000,000 x 100 / 4,000 x 1 exp9 = 0.075 cent / kWh.

According to a 2007 Stanford University study published in the Journal of Applied Meteorology and Climatology, interconnecting ten or more wind farms allows 33 to 47% of the total energy produced to be used as reliable, baseload electric power, as long as minimum criteria are met for wind speed and turbine height.[23][24]

In the UK, demand for electricity is higher in winter than in summer, and so are wind speeds.[31][32][33] Solar power tends to be complementary to wind.[34][35] On daily to weekly timescales, high pressure areas tend to bring clear skies and low surface winds, whereas low pressure areas tend to be windier and cloudier. On seasonal timescales, solar energy typically peaks in summer, whereas in many areas wind energy is lower in summer and higher in winter.[36] Thus the intermittencies of wind and solar power tend to cancel each other somewhat. A demonstration project at the Massachusetts Maritime Academy shows the effect.[37] The Institute for Solar Energy Supply Technology of the University of Kassel pilot-tested a combined power plant linking solar, wind, biogas and hydrostorage to provide load-following power around the clock, entirely from renewable sources.[38]

A report from Denmark noted that their wind power network was without power for 54 days during 2002.[39] Wind power advocates argue that these periods of low wind can be dealt with by simply restarting existing power stations that have been held in readiness or interlinking with HVDC.[25] The cost of keeping a power station idle is in fact quite low, since the main cost of running a power station is the fuel (see spark spread and dark spread).[citation needed]

Penetration

Wind energy "penetration" refers to the fraction of energy produced by wind compared with the total available generation capacity. There is no generally accepted "maximum" level of wind penetration. The limit for a particular grid will depend on the existing generating plants, pricing mechanisms, capacity for storage or demand management, and other factors. An interconnected electricity grid will already include reserve generating and transmission capacity to allow for equipment failures; this reserve capacity can also serve to regulate for the varying power generation by wind plants. Studies have indicated that 20% of the total electrical energy consumption may be incorporated with minimal difficulty.[40] These studies have been for locations with geographically dispersed wind farms, some degree of dispatchable energy, or hydropower with storage capacity, demand management, and interconnection to a large grid area export of electricity when needed. Beyond this level, there are few technical limits, but the economic implications become more significant.

However In evidence to the House of Lords Economic Affairs Select Committee, the UK System Operator, National Grid have quoted estimates of balancing costs for 40% wind and these lie in the range £500-1000M per annum. "These balancing costs represent an additional £6 to £12 per annum on average consumer electricity bill of around £390."[41]

At present, few grid systems have penetration of wind energy above 5%: Denmark (values over 18%), Spain and Portugal (values over 9%), Germany and the Republic of Ireland (values over 6%). The Danish grid is heavily interconnected to the European electrical grid, and it has solved grid management problems by exporting almost half of its wind power to Norway. The correlation between electricity export and wind power production is very strong.[42]

Denmark has active plans to increase the percentage of power generated to over 50%.[43]

A study commissioned by the state of Minnesota considered penetration of up to 25%, and concluded that integration issues would be manageable and have incremental costs of less than one-half cent ($0.0045) per kWh.[44]

ESB National Grid, Ireland's electric utility, in a 2004 study that, concluded that to meet the renewable energy targets set by the EU in 2001 would "increase electricity generation costs by a modest 15%"[45]

A recent report by Sinclair Merz[46] saw no difficulty in accommodating 50% of total power delivered in the UK at modest cost increases.

Predictability

Related to variability is the short-term (hourly or daily) predictability of wind plant output. Like other electricity sources, wind energy must be "scheduled". The nature of this energy source makes it inherently variable. Wind power forecasting methods are used, but predictability of wind plant output remains low for short-term operation.

Turbine placement

Main article: Wind farm

Good selection of a wind turbine site is critical to economic development of wind power. Aside from the availability of wind itself, other factors include the availability of transmission lines, value of energy to be produced, cost of land acquisition, land use considerations, and environmental impact of construction and operations. Off-shore locations may offset their higher construction cost with higher annual load factors, thereby reducing cost of energy produced. Wind farm designers use specialized wind energy software applications to evaluate the impact of these issues on a given wind farm design.

Studies in the UK have shown that if onshore turbines are placed in a straight line then an increased risk of aerodynamic modulation can occur which can result in noise nuisance to nearby residents.

 

Bible Verse of the Day

Our Family of Websites

Energy Sites Family

Our family of Energy/Utility/Lineman/Alternative Resources Websites:

www.powerlinework.com
www.linemanjobs.net
www.energyjobmarket.com

About Us

More about who we are

This is a website built for professionals in the massively growing Energy Industry.

Our goal is to provide you with the latest in Energy job opportunities, the lastest news, and training centers.

The alternative energy/renewable energy industry is just starting to grow. We invite you to join us in making the next step in a better future for our environment.

Why EnergyJobMarket.com

What You'll Receive

You'll receive a Full Page Employment Advertisement
We submit all of our Jobs to all of the major RSS Feeds
Your listing goes on all 3 of our Energy Sites for an even lower rate than 1 site of our competitors
Ability to Edit/Upload and Manage your Advertisement
Easy Payment Options: Invoice or Credit Card and Affordable Rates

Site Sponsors


Hoffman Boots

Far West Line Supply

wesco

ssa1

hwwbanner180x60

jlmatthews



highline

hastings

Stock Trader

Module by: CoreTemplate and StockTrader

Short Term Energy Outlook

Electricity

Consumption.  Total electricity consumption is projected to decline by 0.8 percent in 2009 (U.S. Total Electricity Consumption), including an expected decline of nearly 5 percent in industrial sector electricity sales.  Total electricity consumption is expected to grow by 1.3 percent in 2010 as economic recovery boosts sales of electricity to the residential and commercial sectors.

Prices.  Residential electricity prices, which increased by an estimated 6.5 percent last year, are projected to rise at lower-than-normal annual rates of about 2 percent in 2009 and 2010 (U.S. Residential Electricity Prices).  Industrial electricity prices are expected to increase by just 1 percent in 2009 after having grown by 10 percent last year.

What is Alternative Energy?

Alternative energy is an umbrella term that refers to any source of usable energy intended to replace fuel sources without the undesired consequences of the replaced fuels[1]. Typically, official uses of the term, such as qualification for governmental incentives, exclude fossil fuels and nuclear energy[2][3][4] whose undesired consequences are climate change and difficulties of radioactive waste disposal. Over the years, the nature of what was regarded alternative energy sources has changed considerably, and today because of the variety of energy choices and differing goals of their advocates, defining some energy types as "alternative" is highly controversial.

Define Solar Energy

Solar energy is the radiant light and heat from the Sun that has been harnessed by humans since ancient times using a range of ever-evolving technologies. Solar radiation along with secondary solar resources such as wind and wave power, hydroelectricity and biomass account for most of the available renewable energy on Earth. Only a minuscule fraction of the available solar energy is used.

More About Renewable Energy

Renewable energy is energy generated from natural resources—such as sunlight,[2] wind, rain, tides and geothermal heat—which are renewable (naturally replenished). In 2006, about 18% of global final energy consumption came from renewables, with 13% coming from traditional biomass, such as wood-burning. Hydroelectricity was the next largest renewable source, providing 3% (15% of global electricity generation),[1] followed by solar hot water/heating, which contributed 1.3%. Modern technologies, such as geothermal energy, wind power, solar power, and ocean energy together provided some 0.8% of final energy consumption.[1]